The Fact About Dp50rb That No One Is Suggesting

Learn far better diagnostic data by way of extended watch with the anatomical structure on all convex probes.

iZoom™ allows correct viewing of picture from distance iWorks™ Protocol assists standardize workflow and minimize Test periods

Simply click Agree and Progress to just accept cookies and go on to the website or click on Additional information to see thorough descriptions of the kinds of cookies and decide on no matter if to just accept certain cookies though on the website.

Permits use of many scanned angles to form an individual image, leading to enhanced distinction resolution and enhanced visualization

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Never use any cables apart from the cables delivered Along with the gadget by Mindray. 3. Make use of the cable delivered with This method to attach the printer. Other cables may cause electrical shock. Page 15: Mechanical Safety

General performance Examination five.five.1 Examination Process Resolution Detection depth Geometric Placement Precision Blackout area examination Report the Test photos 5.five.2 Test Content The graphic applied here is only for reference, keep on with the graphic effect in the real Be aware: circumstance. Needs: Screen: established the contrast and brightness with the clinical software price (or perhaps the default status) Procedure atmosphere: dim space, simulating the clinical application surroundings. Site seventy six In condition that the transverse resolution tests targets are horizontally displayed, history the minimum length of two targets that may be Evidently identified. Repeat the operation over to the transverse resolution screening targets at other depths. As shown in determine beneath. Axial resolution ... Page seventy seven When utilizing the convex probe, maintain the transverse resolution tests targets to NOTE: be exhibited close to the midline. When utilizing a linear probe with steer functionality, usually do not turn on the steer function when accomplish the transverse resolution take a look at. Zoom in the location where by the targets Positioned if necessary. The diameter of the focus on stage at a particular depth is equal to the transverse resolution on the depth. Web page seventy eight five.

five.2.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Check Move: Do adjustments as just how in testing the utmost depth. Report the space by 20mm Every section around the longitudinal targets line utilizing the measurement caliper; Find the value with the best mistake (to 20mm), work out the precision utilizing the formula underneath The measurement caliper ought to be positioned for the higher fringe of the goal, Notice:... Webpage 79 Transverse geometric positioning precision  Exam Move: Protect the scan surface on the phantom with Dp50rb login h2o or few gel, gently Call the probe with the scan surface area Regulate the depth, creating the transverse targets being shown while in the graphic. Alter the focus level to get posited beside the transverse targets (the typical is just not very clear) Alter parameters like get, TGC, earning Every transverse targets for being Obviously displayed. Page eighty 5.5.two.4 Blackout Region Check Step: Include the scan surface of the phantom with h2o or pair gel, gently Make contact with the probe Together with the scan surface area Adjust the depth in a reduced value, and established the focus at the closest place to the scan floor. Reduce the worth of parameters like AP, Obtain until the history noise just is usually viewed. Website page eighty one: Program Update And Routine maintenance

Observe: Right before uploading the log, make sure the ultrasound procedure has long been linked to network, otherwise, the program may well warn “couldn't connect with server” The server (smtp.

Soon after changing the CPU module, essential file must be generated Once more according to the new MAC handle and prepared into HDD of the machine. Or else, the configuration purpose of the products are going to be lost. Just after removing the CPU module, Take out panhead screws with washers (twelve M3X6) fastened on the primary unit box, you will take from the board. Website page 118 Figure 8-29 Disassemble the User interface Assembly (1) Keep the upper edge of control panel assembly, and open up up the control panel. Figure 8-30 Disassemble the User interface Assembly (two) After removing one particular countersunk head self-tapping screw PT3X10 set within the user interface and just take out the plug of your keyboard and the key device connecting cables, you could take away the user interface assembly.

If you cease the scanning and the image seize, you ought to ability off the procedure and disconnect the program in the AC ability provide, then pull out AC electric power cables. Website page 109: Battery Connecting Board

Mindray’s new generation of black & white ultrasound procedure, DP-fifty Pro, is supplied with Superior imaging systems permitting deeper penetration and speedier image acquisition with bigger resolution.

probe. The graphic abnormality can be due to Switch the probe, or even the swivel of your 4D probe or maybe the 4D generate replace the 4D generate board board.

NOTE: To the monitor, the brightness adjustment comes just before distinction. Immediately after readjusting the watch’s contrast and brightness, adjust all preset and peripheral configurations.